González Martínez, Antonio Javier
Cargando...
Unidades organizativas
Unidad organizativa
Puesto de trabajo
ORCID
Página personal
Página personal Panorama
Nombre
Dirección de correo electrónico
3 resultados
Resultados de la búsqueda
Mostrando 1 - 3 de 3
- PublicaciónDesign and first results of an innovative and dedicated for hanging breast imaging PET(Bentham Science Publishers, 2012-05-01) González Martínez, Antonio Javier; S Aukema, T.; Barberá Ballester, Julio; Benlloch Baviera, Jose María; Correcher Salvador, Carlos; Orero Palomares, Abel; Soriano Asensi, Antonio; Vogel, W.; Vazquez Barreiros, Carlos; Vidal San Sebastián, Luis Fernando; Valdes Olmos, A.R.; Instituto de Instrumentación para Imagen MolecularIn this work the design and preliminary clinical results obtained with an innovative and dedicated breast PET is presented. A geometrical study clearly pointed out the advantages of the prone position and the technique of hanging breast in comparison to the supine, conventionally used for other imaging modalities. Occult, multifocal and also lesions close to the pectoral muscle were depicted by means of the prone method. The measured diameters of the hanging breasts allowed us to define an optimum transaxial FOV of up to 170 mm. This was achieved by means of 12 detector heads mounted on ring geometry, each using a monolithic LYSO crystal a position sensitive photomultiplier, among other components. The detector showed up an extrinsic spatial resolution as high as 1.4 mm in the center of the FOV with a physical sensitivity of 1.2 %. A clinical trial is undergoing at the Netherlands Cancer Institute in terms of a clinical validation of the dedicated breast PET. An adequate image matching between this device and the whole-body PET was observed, even for deep chest lesions. A preliminary quantitative comparison also shows a good agreement between both systems. However, a tiny deviation to higher Standard Uptake Values is observed for the prototype.
- PublicaciónImplementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET(Elsevier, 2013-02-21) Moliner Martínez, Laura; Correcher, Carlos; González Martínez, Antonio Javier; Conde Castellanos, Pablo Eloy; Hernández Hernández, Liczandro; Orero Palomares, Abel; Rodríguez Álvarez, María José; Sánchez Martínez, Filomeno; Soriano Asensi, Antonio; Vidal San Sebastián, Luis Fernando; Benlloch Baviera, Jose María; Departamento de Matemática Aplicada; Escuela Técnica Superior de Ingeniería Informática; Instituto de Instrumentación para Imagen Molecular; Ministerio de Ciencia e Innovación; Generalitat Valenciana; Centro para el Desarrollo Tecnológico IndustrialIn this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality. © 2012 Elsevier B.V. All rights reserved.
- PublicaciónDiseño y primeros resultados de una cámara PET para animales pequeños basada en cristales LYSO continuos y fotomulplicadores sensibles a la posición(Sociedad Española de Física Médica, 2007) Benlloch Baviera, Jose María; González Martínez, Antonio Javier; Carrilero, V.; Catret, J. V.; Correcher, C.; Lerche, Christoph Werner; Morera, C.; Orero, A.; Pavón, N.; Ros García, Ana; Sánchez, F.; Soriano Asensi, Antonio; Vidal San Sebastián, Luis Fernando; Colom Palero, Ricardo José; Gadea Gironés, Rafael; Herrero Bosch, Vicente; Mora, C.; Mora Mas, Francisco José; Sebastia Cortes, Angel; Munar, A.; Departamento de Ingeniería Electrónica; Escuela Técnica Superior de Ingeniería de Telecomunicación; Instituto de Instrumentación para Imagen Molecular[ES] En este artículo presentamos el diseño de un nuevo escáner PET para animales pequeños basado en una tecnología completamente innovadora. Los resultados preliminares son muy prometedores, permitiendo obtener imágenes funcionales de alta resolución con una instrumentación compacta y de bajo coste. Los prototipos desarrollados se encuentran actualmente en pruebas en diversos centros de investigación médica, obteniéndose imá- genes de alta calidad en los campos de oncología, neurología y cardiología. Este diseño puede ser fácilmente extendido a cámaras PET dedicadas a la exploración del cerebro o de la mama. La innovación más notable de la presente tecnología consiste en el uso de un único cristal continuo por módulo, a diferencia de otras cámaras PET comerciales donde se utilizan cientos de cristales pixelados. El uso de un único cristal continuo permite abaratar el coste de fabricación, al tiempo que mejora las características de funcionamiento: resolución intrínseca en posición de 1,2 mm, resolución en energía media del 14%, resolución en la profundidad de interacción de 3 mm, sensibilidad > 4% y campo de visión transaxial de 80 mm de diámetro. En el presente artículo se describen en detalle el diseño de esta nueva cámara PET, los principios de funcionamiento, el método utilizado para su calibración y se anticipan algunas imágenes "in vivo" del miocardio y el cerebro de un ratón, permitiendo apreciar de forma preliminar la resolución y calidad alcanzadas.