González Martínez, Antonio Javier

Cargando...
Foto de perfil
Puesto de trabajo
ORCID
Página personal Panorama
Nombre
Dirección de correo electrónico

Resultados de la búsqueda

Mostrando 1 - 4 de 4
  • Publicación
    PETIROC2 based readout electronics optimization for Gamma Cameras and PET detectors
    (IOP Publishing, 2017) Monzó Ferrer, José María; Aguilar -Talens, Albert; González Montoro, Andrea; Lamprou,E.; González Martínez, Antonio Javier; Hernández Hernández, Liczandro; Mázur, Dmytro; Colom Palero, Ricardo José; Benlloch Baviera, Jose María; Departamento de Ingeniería Electrónica; Escuela Técnica Superior de Ingeniería de Telecomunicación; Instituto de Instrumentación para Imagen Molecular; Ministerio de Economía, Industria y Competitividad
    [EN] Developing front-end electronics to improve charge detection and time resolution in gamma-ray detectors is one of the main tasks to improve performance in new multimodal imaging systems that merge information of Magnetic Resonance Imaging and Gamma Camera or PET tomographs. The aim of this work is to study the behaviour and to optimize the performance of an ASIC for PET and Gamma Camera applications based on SiPMs detectors. PETIROC2 is a commercial ASIC developed by Weeroc to provide accurate charge and time coincidence resolutions. It has 32 analog input channels that are independently managed. Each channel is divided into two signals, one for time stamping using a TDC and another for charge measurement. In this work, PETIROC2 is evaluated in an experimental setup composed of two pixelated LYSO crystals based detectors, each coupled to a Hamamatsu 4 x 4 SiPM array. Both detectors are working in coincidence with a separation distance between them that can be modified. In the present work, an energy resolution of 13 : 6% FWHM and a time coincidence resolution of 815 ps FWHM have been obtained. These results will be useful to optimize and improve PETIROC2 based PET and Gamma Camera systems.
  • Publicación
    TOF studies for dedicated PET with open geometries
    (IOP Publishing, 2019-02) Moliner Martínez, Laura; Ilisie, V.; González Martínez, Antonio Javier; Oliver Gil, Sandra; Gonzalez, A.; Giménez-Alventosa, Vicent; Cañizares, G.; Lamprou, E.; Alamo, J.; Rodríguez Álvarez, María José; Sánchez Martínez, Filomeno; Benlloch Baviera, Jose María; Departamento de Física Aplicada; Departamento de Matemática Aplicada; Escuela Técnica Superior de Ingeniería Industrial; Instituto Universitario de Seguridad Industrial, Radiofísica y Medioambiental; Escuela Técnica Superior de Ingeniería Informática; Instituto de Instrumentación para Imagen Molecular; European Commission; Ministerio de Economía y Competitividad
    [EN] Recently, two novel PET devices have been developed with open geometries, namely: breast and prostate-dedicated scanners. The breast-dedicated system comprises two detector rings of twelve modules with a field of view of 170 mm x 170 mm x 94 mm. Each module consists of a continuous trapezoidal LYSO crystal and a PSPMT. The system has the capability to vary the opening of the rings up to 60 mm in order to allow the insertion of a needle to perform a biopsy procedure. The prostate system has an open geometry consisting on two parallel plates separated 28 cm. One panel includes 18 detectors organized in a 6 x 3 matrix while the second one comprises 6 detectors organized in a 3 x 2 matrix. All detectors are formed by continuous LYSO crystals of 50 mm x 50 mm x15 mm, and a SiPM array of 12 x 12 individual photo-detectors. The system geometry is asymmetric maximizing the sensitivity of the system at the prostate location, located at about 2/3 in the abdomen-anus distance. The reconstructed images for PET scanners with open geometries present severe artifacts due to this peculiarity. These artifacts can be minimized using Time Of Flight information (TOF). In this work we present a TOF resolution study for open geometries. With this aim, the dedicated breast and prostate systems have been simulated using GATE (8.1 version) with different TOF resolutions in order to determine the image quality improvements that can be achieved with the existing TOF-dedicated electronics currently present in the market. The images have been reconstructed using the LMOS algorithm including TOF modeling in the calculation of the voxel-Line Of Response emission probabilities.
  • Publicación
    Programmable integrated front-end for SiPM/PMT PET detectors with continuous scintillating crystal
    (IOP Publishing: Hybrid Open Access, 2012-12) Herrero Bosch, Vicente; Monzó Ferrer, José María; Ros García, Ana; Aliaga Varea, Ramón José; González Martínez, Antonio Javier; Montoliu, C.; Colom Palero, Ricardo José; Benlloch Baviera, Jose María; Departamento de Ingeniería Electrónica; Escuela Técnica Superior de Ingeniería de Telecomunicación; Instituto Universitario de Matemática Pura y Aplicada; Instituto de Instrumentación para Imagen Molecular; Universitat Politècnica de València
    [EN] AMIC architecture has been introduced in previous works in order to provide a generic and expandable solution for implementing large number of outputs SiPM array/PMT detectors. The underlying idea in AMIC architecture is to calculate the moments of the detected light distribution in an analog fashion. These moments provide information about energy, x/y position, etc. of the light distribution of the detected event. Moreover this means that a small set of signals contains most of the information of the event, thus reducing the number of channels to be acquired. This paper introduces a new front-end device AMIC2GR which implements the AMIC architecture improving the features of the former integrated devices. Higher bandwidth and filtering coefficient precision along with a lower noise allow to apply some detector enhancements. Inhomogeneity among detector elements throughout the array can be reduced. Depth of interaction measurements can be obtained from the light distribution analysis. Also a common trigger signal can be obtained for the whole detector array. Finally AMIC2GR preamplifier stage close to SiPM output signals optimizes signal to noise ratio, which allows to reduce SiPM gain by using lower operating voltages thus reducing dark noise
  • Publicación
    A scintillator geometry suitable for very small PET gantries
    (IOP Publishing, 2017-12-11) González Martínez, Antonio Javier; Gonzalez-Montoro, A.; Aguilar, A.; Cañizares, G.; Martí, R.; Iranzo, S.; Lamprou, E.; Sánchez, S.; Sánchez Martínez, Filomeno; Benlloch Baviera, Jose María; Instituto de Instrumentación para Imagen Molecular; European Commission; Ministerio de Economía y Competitividad; Secretaría de Estado de Investigación, Desarrollo e Innovación